List of accessories
(Contact Angle Measuring Instruments)
DSA14
| Back to instrument page |  |
SW4021 | DSA4 Software to determine static and dynamic contact angles using sessile drop and captive bubble method |  |
SW4022 | DSA4 Software to determine surface free energy of solids from contact angle data, for the systems DSA20B, DSA15B and DSA14. |  |
SW4023 | DSA4 Software to determine surface and interfacial tension of liquids by analysis of pendant drops, for the systems DSA20B, DSA20S, DSA15B, DSA15S and DSA14. |  |
DS4000 | Direct Dosing System, manual, with disposable syringes SY3040 (3 ml) consisting of: · Syringe adapter for disposable syringes SY3040 (3 ml) · 1 disposable syringe SY3040 (3 ml) · 1 piston for precise dosing · 5 dosing needles: diameter 0.5 mm, length 38 mm (NE44) · 5 dosing needles: diameter 1.8 mm, length 38 mm (NE45) for the systems DSA15 series, DSA16 and DSA14
|  |
DS4001 | Double Direct Dosing System, manual, with 2 glass syringes SY40 (1 ml) consisting of: · 2 Syringe adapters for glass syringes SY40 (1 ml) with micrometer screws · 2 glass syringes SY40 (1 ml) · 10 dosing needles: diameter 1.1 mm, length 28 mm (NE42) · 10 dosing needles: diameter 0.7 mm, length 28 mm (NE43) for the systems DSA15/DSA20 series, DSA16 and DSA14 |  |
PS4010 | Pick-Up Stage (100 x 100 mm, W x D), manual stage with flexible positioning in x/y-direction. Specially designed to pick up the droplet from the syringe needle tip, for maximum sample size of up to 300 x oo x 50 mm (W x D x H). The Pick-Up stage cannot be used in conjunction with any measuring chamber. |  |
PS3244 | Manual Micro Positioning x/y-stage for precise positioning of small samples, can be used with PS4000/PS3202/PS3205/PS3250, incl. sample stage 100 × 100 mm (L × W) and additional sample stage 95 × 30 mm (L × W) for micro applications, for samples up to 0.5 kg, with clamps for samples with thickness up to 2 mm. Moving range: x=30 mm, y=50 mm. Suitable for DSA100, DSA30, DSA14 and EasyDrop series.
|  |
ST01 | Suction Plate for fixation of flexible samples like films, foils etc. incl. fitting connection for a vacuum pump. Max. thickness of sample is 25 mm. |  |
ST02 | Special Sample Holder made of POM for contact angle measurements on thin films and foils. |  |
ST03 | Powder Sample Holder for sessile drop method. |  |
ST04 | Special Sample Holder for Films and Paper Max. sample size: 80 × 80 × 4 mm (L × W × H). |  |
TC3010 | Environmental Chamber · Sample chamber size: 90 × 90 × 30 mm (L × W × H) · Min./max. allowed flow temperature: -10°C (263 K) / 120°C (393 K), connectable to a circulator · Inert gas inlet · 3 windows in the chamber: - 2 parallel to the optical axis - 1 perpendicular to the optical axis · Easily exchangeable covers: - 1 used for elevated temperatures and inert gas - 2 used for measurements at different positions on the same surface · Temperature probe Pt100 When used with tilting table PA3220 please also order SP3010.
|  |
TC11 | Environmental Chamber for very large samples · Sample chamber for max. sample size: 132 × 132 × 27 mm (L × W × H) · Min./max. allowed flow temperature: -10°C (263 K) / 120°C (393 K), to be connected to a circulator · Inert gas inlet · 3 windows: - 2 parallel to the optical axis - 1 perpendicular to the optical axis · Samples position adjustable from outside perpendicular to optical axis, to measure various positions · 2 sample stages for optimal positioning of samples with different geometry · Special device for small sample positioning · Temperature probe Pt100
|  |
TC40MK2 | Environmental Chamber for fast temperature changes Peltier Temperature Chamber including electronic, min./max. allowed temperature inside the cooling jacket: 5°C (278 K) / 90°C (363 K), operating temperature inside the base plate: -30°C (243 K) / 160°C (433 K), with inert gas inlet, consisting of: · 1 Peltier Temperature Chamber with 3 windows of optical special glass with gas-rinsing of windows to avoid steaming-up · 1 internal sample stage moveable across the optical axis for sample positioning without opening the chamber · 2 Pt100 as temperature probe and control probe · 1 Temperature controller with a resolution of 0.1 K This assembly is usable to -60°C (213 K) Sample chamber size: 100 × 100 × 25 mm (L × W × H). When used with heat conducting hood to reducce the temperature gradients: 80 × 80 × 20 mm (L × W × H). Counter-cooling required (recommended: TB14). In combination with HC10 the temperature range is reduced to 5°C (278 K) / 90°C (363 K)
|  |
TC3013 | External temperature display Range of display: -10°C to 199.9°C (263-472.9 K), resolution: 0.1K |  |
CP23 | Contact Angle Standard Set for testing of contact angle measurement, consisting of: · 3 optical contact angle standards (30°, 60°, 120°) according to Young-Laplace model
|  |
CP24 | Contact Angle Standard Set with certificate documenting the precision of the drop shape from which the contact angle is derived, for testing of contact angle measurement, consisting of: · 3 optical contact angle standards (30°, 60°, 120°) according to Young-Laplace model
|  |
CP29 | Contact Angle Standard Set for testing of contact angle measurement, consisting of: · 1 optical contact angle standard (10°) for circular shape method
|  |
CP25 | Pendant Drop Standard Set for testing of the surface tension measurement, consisting of: · 2 optical Pendant Drop Standards (20 mN/m, 50 mN/m) according to Young-Laplace model
|  |
CP26 | Pendant Drop Standard Set with certificate documenting the precision of the drop shape from which surface and interfacial tension is derived, for testing of the surface tension measurement, consisting of: · 2 optical Pendant Drop Standards (20 mN/m, 50 mN/m) according to Young-Laplace model
|  |
SC01 | Glass Cuvette made of optical glass for measurements of interfacial tensions between two liquids using the pendant drop method. Inner dimensions: 20 × 20 × 20 mm (L × W × H). |  |
SC02 | Glass Cuvette made of optical glass in one distortion-free, preferred orientation, for measurements of interfacial tension between two liquids using the pendant drop method. Inner dimensions: 40 × 40 × 30 mm (L × W × H). |  |
SC04 | Glass Cuvette made of optical glass in one distortion-free, preferred orientation, for measurements of interfacial tensions between two liquids using the pendant drop method. Inner dimensions: 40 × 40 × 20 mm (L × W × H). Suitable for measurements in the environmental chambers TC3010, TC30, TC40, TC40MK2, TC11. |  |
SC22 | Glass Cuvette made of optical glass for measurements of interfacial tensions between two liquids when dosing the specific lighter phase, including one special designed needle NE21| (with Luer-Lock-Connector, without syringe). Inner dimensions: 20 x 20 x 20 mm (L x W x H). Needle diameter: 1.5 mm. |  |
SC23 | Glass Cuvette made of optical glass to measure contact angle of liquid droplets or gas bubbles in liquid, incl. specially designed needle NE22 (with Luer-Lock-Connector) and solid sample support. Inner dimensions: 40 x 20 x 11 mm (L x W x H). Needle diameter: 0.5 mm. |  |
SC30 | Glass Cuvette made of optical glass temperature maintained by liquid. For measurements of interfacial tension between two liquids, temperature range: 5°C-90°C, incl. tubing (silicone) and quick connectors 10 mm. Inner dimensions: 30 x 20 x 30 mm (L x W x H). |  |
ST10MK2 | Glass Cuvette made of optical glass to measure contact angle of liquid droplets or gas bubbles in liquid, incl. specially designed needle NE22 (with Luer-Lock-Connector) and holder for contact lenses, films and flat samples as well as glass cuvette SC02 with inner dimensions: 40 × 40 × 30 mm (L × W × H). Needle diameter: 0.6 mm.
|  |
SY40 | 1 ml Glass Syringe, Luer-Lock, without needle, for DS4001/DS4002 |  |
SY3040 | 3 ml Disposable Syringe, Luer-Lock, without needle, set of 100 pieces. |  |
SY3701 | 1 ml Disposable Syringe, Luer, without needle, set of 100 pieces. |  |
NE21 | Curved Needle, Luer-Lock, for interfacial tension measurements on rising bubble Outer needle diameter: 1.5 mm, length: 51 mm |  |
NE22 | Curved Needle, Luer-Lock, for captive bubble measurements Outer needle diameter: 0.6 mm, length: 51 mm |  |
NE25 | Curved Needle, Luer-Lock, for interfacial tension measurements on rising bubble Outer needle diameter: 0.9 mm, length: 42 mm |  |
NE26 | Curved Needle, Luer-Lock, for interfacial tension measurements on rising bubble Outer needle diameter: 1.4 mm, length: 42 mm |  |
NE27 | Curved Needle, Luer-Lock, for interfacial tension measurements on rising bubble Outer needle diameter: 1.8 mm, length: 42 mm |  |
NE14 | Needle, Luer-Lock, for G10, DO3010 and single dosing system of G2, suitable for syringe SY20 with TC20 Needle diameter: 0.6 mm, length: 25 mm |  |
NE23 | Needle, Luer-Lock, for G10, DO3010, single dosing system of G2 and Multi Dosing System DO3020/DO3021 of DSA10, suitable for syringe SY20 and SY3040 Outer needle diameter: 0.6 mm, length: 30 mm |  |
NE28 | Needle, Luer-Lock, for contact angle measurements Outer needle diameter: 0.3 mm, length: 30 mm |  |
NE24 | Needle, Luer-Lock, for pendant drop measurements Outer needle diameter: 1.5 mm, length: 30 mm |  |
NE29 | Needle, Luer-Lock, for pendant drop measurements Outer needle diameter: 2 mm, length: 30 mm |  |
NE40 | Hollow needle, Luer-Lock (set of 25 pieces) for G10, DO3010, Single Dosing System of G2 and Multi Dosing System DO3020/DO3021 of DSA10, suitable for syringe SY20, SY3010 and SY3040. Needle diameter: 1.8 mm, length: 28 mm |  |
NE41 | Hollow needle, Luer-Lock (set of 25 pieces) for G10, DO3010, Single Dosing System of G2 and Multi Dosing System DO3020/DO3021 of DSA10, suitable for syringe SY20, SY3010 and SY3040. Needle diameter: 0.5 mm, length: 28 mm |  |
NE42 | Hollow needle with removable PTFE-tube, Luer-Lock (set of 25 pieces) for G10, DO3010, Single Dosing System of G2 and Multi Dosing System DO3020/DO3021 of DSA10 suitable for syringe SY20, SY40, SY3010 and SY3040. Needle diameter: 1.1 mm, length: 28 mm |  |
NE43 | Hollow needle with removable PTFE-tube, Luer-Lock (set of 25 pieces) for G10, DO3010, Single Dosing System of G2 and Multi Dosing System DO3020/DO3021 of DSA10 suitable for syringe SY20, SY40, SY3010 and SY3040. Needle diameter: 0.7 mm, length: 28 mm |  |
NE44 | Disposable dosing needles, Luer-Lock (set of 50 pieces) for contact angle measurements Needle diameter: 0.5 mm, length: 38 mm |  |
NE45 | Disposable dosing needles, Luer-Lock (set of 50 pieces) for pendant drop measurements Needle diameter: 1.8 mm, length: 38 mm |  |
NE31 | Needle, Luer-Lock, PTFE coated, coated length: 30 mm, metal hub, outer needle diameter (without coating): 0.52±0.01 mm, length: 38 mm, gauge 25 |  |
NE32 | Needle, Luer-Lock, PTFE coated, coated length: 30 mm, metal hub, outer needle diameter (without coating): 1.07±0.015 mm, length: 38 mm, gauge 19 |  |
NE33 | Needle, Luer-Lock, PTFE coated , coated length: 30 mm, metal hub, outer needle diameter (without coating): 2.11±0.025 mm, length: 38 mm, gauge 14 |  |