List of accessories
(Contact Angle Measuring Instruments)

EasyDrop

Back to instrument page

SW4021

DSA4 Software to determine static and dynamic contact angles
using sessile drop and captive bubble method

SW4022

DSA4 Software to determine surface free energy of
solids from contact angle data,
for the systems DSA20B, DSA15B and DSA14.

SW4023

DSA4 Software to determine surface and interfacial tension
of liquids by analysis of pendant drops,
for the systems DSA20B, DSA20S, DSA15B, DSA15S and DSA14.

DS4000

Direct Dosing System, manual,
with disposable syringes SY3040 (3 ml)
consisting of:
·  Syringe adapter for disposable syringes SY3040 (3 ml)
·  1 disposable syringe SY3040 (3 ml)
·  1 piston for precise dosing
·  5 dosing needles: diameter 0.5 mm, length 38 mm (NE44)
·  5 dosing needles: diameter 1.8 mm, length 38 mm (NE45)
for the systems DSA15 series, DSA16 and DSA14

DS4010

Single Direct Dosing System, Software-controlled,
with glass syringe SY20 (500 µl), without tubings,
specially designed for hazardous, and/or difficult to clean
test liquids, consisting of:
·  1 DO4010 Direct dosing system for 1 liquid,
   Software-controlled
·  1 DA3205, Adapter with glass syringe SY20 (500 µl)
   including:
   - 1 glass syringe SY20 (500 µl)
   - 5 dosing needles: diameter 0.5 mm, length 38 mm (NE44)
   - 5 dosing needles: diameter 1.8 mm, length 38 mm (NE45)
for the systems DSA20 series

TC3012

Temperature Control of Measuring Liquids
for DO3001, DO3003, DO3004, G2 standard dosing system,
DS3210, DS4210 and DS4010, for disposable syringes
SY3701 (1 ml), temperature range: 5-90°C (278-363 K).

DS4001

Double Direct Dosing System, manual,
with 2 glass syringes SY40 (1 ml)
consisting of:
·  2 Syringe adapters for glass syringes SY40 (1 ml)
   with micrometer screws
·  2 glass syringes SY40 (1 ml)
·  10 dosing needles: diameter 1.1 mm, length 28 mm (NE42)
·  10 dosing needles: diameter 0.7 mm, length 28 mm (NE43)
for the systems DSA15/DSA20 series, DSA16 and DSA14

PS4000

Standard Sample Stage (100 x 100 mm, W × D),
manual stage with flexible positioning in x/y-direction,
for maximum sample size of up to
300×∞×50 mm (W × D × H).

PS4010

Pick-Up Stage (100 x 100 mm, W x D),
manual stage with flexible positioning in x/y-direction.
Specially designed to pick up the droplet from the syringe
needle tip, for maximum sample size of up to
300 x oo x 50 mm (W x D x H).
The Pick-Up stage cannot be used in conjunction with
any measuring chamber.

ST01

Suction Plate
for fixation of flexible samples like films, foils etc.
incl. fitting connection for a vacuum pump. 
Max. thickness of sample is 25 mm.

ST02

Special Sample Holder
made of POM for contact angle measurements on thin films
and foils.

ST03

Powder Sample Holder
for sessile drop method.

ST04

Special Sample Holder for Films and Paper
Max. sample size: 80 ×  80 × 4 mm (L × W × H).

ST10MK2

Glass Cuvette made of optical glass
to measure contact angle of liquid droplets or gas bubbles
in liquid, incl. specially designed needle NE22
(with Luer-Lock-Connector) and holder for contact lenses,
films and flat samples as well as glass cuvette SC02
with inner dimensions:  40 × 40 × 30 mm (L × W × H).
Needle diameter: 0.6 mm.

PS3244

Manual Micro Positioning x/y-stage
for precise positioning of small samples,
can be used with PS4000/PS3202/PS3205/PS3250,
incl. sample stage 100 × 100 mm (L × W) and additional
sample stage 95 × 30 mm (L × W) for micro applications,
for samples up to 0.5 kg, with clamps for samples
with thickness up to 2 mm.
Moving range: x=30 mm, y=50 mm.
Suitable for DSA100, DSA30, DSA14 and EasyDrop series.

TC3010

Environmental Chamber
·   Sample chamber size: 90 × 90 × 30 mm (L × W × H)
·   Min./max. allowed flow temperature: -10°C (263 K) /
    120°C (393 K), connectable to a circulator
·   Inert gas inlet
·   3 windows in the chamber:
     - 2 parallel to the optical  axis
     - 1 perpendicular to the optical axis
·   Easily exchangeable covers:
     - 1 used for elevated temperatures and inert gas
     - 2 used for measurements at different positions on
       the same surface
·   Temperature probe Pt100
When used with tilting table PA3220 please also order
SP3010.

TC11

Environmental Chamber for very large samples
·   Sample chamber for max. sample size: 132 × 132 × 27 mm
   (L × W × H)
·   Min./max. allowed flow temperature: -10°C (263 K) /
    120°C (393 K), to be connected  to a circulator
·   Inert gas inlet
·   3 windows:
     - 2 parallel to the optical  axis
     - 1 perpendicular to the optical axis
·   Samples position adjustable from outside perpendicular
    to optical axis, to measure various positions
·   2 sample stages for optimal positioning of samples
    with different geometry
·   Special device for small sample positioning
·   Temperature probe Pt100

TC40MK2

Environmental Chamber for fast temperature changes
Peltier Temperature Chamber including electronic,
min./max. allowed temperature inside the cooling jacket:
5°C (278 K) / 90°C (363 K), operating temperature inside
the base plate: -30°C (243 K) / 160°C (433 K),
with inert gas inlet, consisting of:
·   1 Peltier Temperature Chamber with 3 windows of
    optical special glass with gas-rinsing of windows
    to avoid steaming-up
·   1 internal sample stage moveable
    across the optical axis for sample positioning
    without opening the chamber
·   2 Pt100 as temperature probe and control probe
·   1 Temperature controller with a resolution of 0.1 K
This assembly is usable to -60°C (213 K)
Sample chamber size: 100 × 100 × 25 mm (L × W × H).
When used with heat conducting hood to reducce
the temperature gradients: 80 × 80 × 20 mm (L × W × H).
Counter-cooling required (recommended: TB14).
In combination with HC10 the temperature range is reduced
to 5°C (278 K) / 90°C (363 K)


CP23

Contact Angle Standard Set
for testing of contact angle measurement, consisting of:
·   3 optical contact angle standards (30°, 60°, 120°)
    according to Young-Laplace model

CP24

Contact Angle Standard Set with certificate documenting
the precision of the drop shape from which the contact
angle is derived,
for testing of contact angle measurement, consisting of:
·   3 optical contact angle standards (30°, 60°, 120°)
    according to Young-Laplace model

CP29

Contact Angle Standard Set
for testing of contact angle measurement, consisting of:
·   1 optical contact angle standard (10°)
    for circular shape method

CP25

Pendant Drop Standard Set
for testing of the surface tension measurement,
consisting of:
·   2 optical Pendant Drop Standards (20 mN/m, 50 mN/m)
   according to Young-Laplace model

CP26

Pendant Drop Standard Set with certificate documenting
the precision of the drop shape from which surface and
interfacial tension is derived, for testing of the surface
tension measurement, consisting of:
·   2 optical Pendant Drop Standards (20 mN/m, 50 mN/m)
    according to Young-Laplace model

CP52

Levelling Device for setting and checking the horizontal arrangement of the instrument

SC01

Glass Cuvette made of optical glass
for measurements of interfacial tensions
between two liquids using the pendant drop method.
Inner dimensions: 20 × 20 × 20 mm (L × W × H).

SC02

Glass Cuvette made of optical glass
in one distortion-free, preferred orientation,
for measurements of interfacial tension
between two liquids using the pendant drop method.
Inner dimensions: 40 × 40 × 30 mm (L × W × H).

SC04

Glass Cuvette made of optical glass
in one distortion-free, preferred orientation,
for measurements of interfacial tensions
between two liquids using the pendant drop method.
Inner dimensions: 40 × 40 × 20 mm (L × W × H).
Suitable for measurements in the environmental chambers
TC3010, TC30, TC40, TC40MK2, TC11.

SC22

Glass Cuvette made of optical glass
for measurements of interfacial tensions
between two liquids when dosing the specific lighter phase,
including one special designed needle NE21|
(with Luer-Lock-Connector, without syringe).
Inner dimensions: 20 x 20 x 20 mm (L x W x H).
Needle diameter: 1.5 mm.

SC23

Glass Cuvette made of optical glass
to measure contact angle of liquid droplets or gas bubbles
in liquid, incl. specially designed needle NE22
(with Luer-Lock-Connector) and solid sample support.
Inner dimensions:  40 x 20 x 11 mm (L x W x H).
Needle diameter:   0.5 mm.

SC30

Glass Cuvette made of optical glass
temperature maintained by liquid.
For measurements of interfacial tension
between two liquids, temperature range: 5°C-90°C,
incl. tubing (silicone) and quick connectors 10 mm.
Inner dimensions: 30 x 20 x 30 mm (L x W x H).

SY10

100 µl Glass Syringe, Luer-Lock, without needle,
allows dosing steps of  0.01 µl.
Suitable for all motorized dosing systems except DO322xMK2.

SY20

500 µl Glass Syringe, Luer-Lock, without needle,
allows dosing steps of  0.06 µl.
Suitable for all motorized dosing systems except DO322xMK2.

SY40

1 ml  Glass Syringe, Luer-Lock, without needle,
for DS4001/DS4002

SY3040

3 ml Disposable Syringe, Luer-Lock, without needle,
set of 100 pieces.

SY3701

1 ml Disposable Syringe, Luer, without needle,
set of 100 pieces.

NE21

Curved Needle, Luer-Lock, for interfacial tension
measurements on rising bubble
Outer needle diameter: 1.5 mm, length: 51 mm

NE22

Curved Needle, Luer-Lock, for captive bubble measurements
Outer needle diameter: 0.6 mm, length: 51 mm

NE25

Curved Needle, Luer-Lock, for interfacial tension
measurements on rising bubble
Outer needle diameter: 0.9 mm, length: 42 mm

NE26

Curved Needle, Luer-Lock, for interfacial tension
measurements on rising bubble
Outer needle diameter: 1.4 mm, length: 42 mm

NE27

Curved Needle, Luer-Lock, for interfacial tension
measurements on rising bubble
Outer needle diameter: 1.8 mm, length: 42 mm

NE14

Needle, Luer-Lock, for G10, DO3010 and single dosing system
of G2, suitable for syringe SY20 with TC20
Needle diameter: 0.6 mm, length: 25 mm

NE23

Needle, Luer-Lock, for G10, DO3010, single dosing system of
G2 and Multi Dosing System DO3020/DO3021 of DSA10,
suitable for syringe SY20 and SY3040
Outer needle diameter: 0.6 mm, length: 30 mm

NE28

Needle, Luer-Lock, for contact angle measurements
Outer needle diameter: 0.3 mm, length: 30 mm

NE24

Needle, Luer-Lock, for pendant drop measurements
Outer needle diameter: 1.5 mm, length: 30 mm

NE29

Needle, Luer-Lock, for pendant drop measurements
Outer needle diameter: 2 mm, length: 30 mm

NE40

Hollow needle, Luer-Lock (set of 25 pieces)
for G10, DO3010, Single Dosing System of G2 and
Multi Dosing System DO3020/DO3021 of DSA10,
suitable for syringe SY20, SY3010 and SY3040.
Needle diameter: 1.8 mm, length: 28 mm

NE41

Hollow needle, Luer-Lock (set of 25 pieces)
for G10, DO3010, Single Dosing System of G2 and
Multi Dosing System DO3020/DO3021 of DSA10,
suitable for syringe SY20, SY3010 and SY3040.
Needle diameter: 0.5 mm, length: 28 mm

NE42

Hollow needle with removable PTFE-tube, Luer-Lock
(set of 25 pieces)
for G10, DO3010, Single Dosing System of G2 and
Multi Dosing System DO3020/DO3021 of DSA10
suitable for syringe SY20, SY40, SY3010 and SY3040.
Needle diameter: 1.1 mm, length: 28 mm

NE43

Hollow needle with removable PTFE-tube, Luer-Lock
(set of 25 pieces)
for G10, DO3010, Single Dosing System of G2 and
Multi Dosing System DO3020/DO3021 of DSA10
suitable for syringe SY20, SY40, SY3010 and SY3040.
Needle diameter: 0.7 mm, length: 28 mm

NE44

Disposable dosing needles, Luer-Lock (set of 50 pieces)
for contact angle measurements
Needle diameter: 0.5 mm, length: 38 mm

NE45

Disposable dosing needles, Luer-Lock (set of 50 pieces)
for pendant drop measurements
Needle diameter: 1.8 mm, length: 38 mm

NE31

Needle, Luer-Lock, PTFE coated,
coated length: 30 mm, metal hub, outer needle diameter
(without coating): 0.52±0.01 mm, length: 38 mm, gauge 25

NE32

Needle, Luer-Lock, PTFE coated,
coated length: 30 mm, metal hub, outer needle diameter
(without coating): 1.07±0.015 mm, length: 38 mm, gauge 19

NE33

Needle, Luer-Lock, PTFE coated ,
coated length: 30 mm, metal hub, outer needle diameter
(without coating): 2.11±0.025 mm, length: 38 mm, gauge 14

NE34

Needle, Luer-Lock, PTFE coated ,
coated length: 30 mm, metal hub, outer needle diameter
(without coating): 3.05±0.01 mm, length: 38 mm, gauge 11